Research Article - Interventional Cardiology (2018) Volume 10, Issue 3

A Novel Guide Wire Facilitates Percutaneous and Nofluoroscopic Procedure for Atrial Septal Defect Closure

Corresponding Author:
Xiangbin Pa
National Center for Cardiovascular Disease
Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
Tel: +86(10)88396666
E-mail: fuwaiyiyuan28@163.com

Received date: May 21, 2018 Accepted date: June 04, 2018 Published date: June 11, 2018

Abstract

Objective: The purpose of this pilot study was to assess the safety and efficacy of a novel ultrasound guided wire for the treatment of patients with atrial septal defect (ASD) who underwent percutaneous atrial septal defect closure using transthoracic echocardiographic (TTE) guidance only.

Materials and methods: From November 2017 to December 2017, 10 patients with congenital ASD were recruited for echo-guiding occlusion with a new designed wire specialized for percutaneous and no-fluoroscopic procedure. The novelty of this wire lies in the elastic spindleshaped tip which helps with precise positioning under ultrasound while reducing difficulty and complications. Operations were performed by 3 doctors who had performed no more than 10 echo-guided cases. Operative successful rate was used as the main evaluation index, Secondary evaluation index included operative time, the number of times guide wire or delivery system dropped into right atrial, frequency of arrhythmia, the number of times guide wire went through tricuspid valve, cardiac perforation, cardiac tamponade and peripheral vascular complications.

Result: All 10 patients successfully underwent percutaneous and no-fluoroscopic atrial septal defect closure with the novel wire. The mean operation time was 20.20±8.904 minutes. The followup time was 3 months and no severe complication occurred. Conclusion: This pilot study demonstrated that the new ultrasound guided wire can be precisely positioned under ultrasound and can facilitate percutaneous and no fluoroscopic procedure safely and effectively.

Retraction Note

The article entitled “A novel guide wire facilitates percutaneous and nofluoroscopic procedure for atrial septal defect closure,” has been accepted for publication in the Interventional Cardiology considering the statements provided in the article as personal opinion of the author which was found not having any conflict or biasness towards anything. As the article was a perspective one, information provided by the author was considered as an opinion to be expressed through publication.

Publisher took decision to make the article online solely based on the reviewers suggestion which considered the article not but a personal opinion of the author. However, it is found that the author have some personal concerns and issues, therefore, being retracted from the journal.

Awards Nomination 20+ Million Readerbase

Select your language of interest to view the total content in your interested language

Journal Metrics:

Impact Factor 1.34
Scimago Journal Rank (SJR) 123
SJR Total Cites 15
Source Normalized Impact per Paper (SNIP) 0.144
h-index (2023) 12
PubMed NLM ID:  10148499
Google Scholar h5 index: 6
Iindex Copernicus Value: 105.52


Google Scholar citation report
Citations : 1297

Interventional Cardiology received 1297 citations as per Google Scholar report


Interventional Cardiology peer review process verified at publons

Indexed In

flyer